PCI Reinforcement Mat GFM 1 lfm x 0.90 m Glass Fiber as Meterware
- Alkali-resistant: The glass fibers exhibit long-term stability in both alkaline and acidic media
- High tensile strength and high elasticity modulus for effective reinforcement of tensile and bending tensile strength of suitable PCI floor leveling compounds
- Simple installation
- Fast construction progress
- High application safety, as confirmed by the TU Munich investigation report
- Minimal system build-up height with suitable PCI floor leveling compounds from 5 mm
PCI Reinforcement Mat GFM
- Contains a special binder that holds the glass fibers together in mat form in the delivery state and does not interfere when in contact with suitable PCI floor leveling compounds
- No disruption of the bond due to a separating coating on the reinforcement between fiber and PCI floor leveling compound on one side and PCI floor leveling compound and primed substrate on the other
- The reinforcement fibers remain highly concentrated, surface-active, acting in all horizontal directions within the lower boundary layer of the leveling layer
- Complete encapsulation of the reinforcement fibers by the PCI floor leveling compound possible
PCI Reinforcement Mat GFS
- Fiber length with fine adhesion thread grid and peel-off mesh foil fixed
- Easy handling and embedding in suitable PCI floor leveling compounds
- No floating of the reinforcement
- Color: white
- Delivery form: 1 to 100 lfm roll, 100 m
Application Area
- For reinforcement and reinforcement of tensile strength of suitable cement-based PCI floor leveling compounds for a bonded leveling in layer thicknesses from 5 mm
- On substrates with existing cracks and false joints
- On crack-prone substrates and mixed substrates
- On lightly vibrating or vibration-prone substrates, e.g., wooden floor constructions
- PCI Reinforcement Mat GFM
- On substrates with cracks up to approx. 3 mm crack width and low expected movements
Substrate Preparation
Suitable substrates for the used PCI floor leveling compound are suitable. Existing cracks do not need to be permanently closed. Substrate preparation must otherwise be carried out according to the technical data sheet of the used PCI floor leveling compound.
Priming
Depending on the existing substrate, the appropriate primer must be applied as specified in the technical data sheet of the used PCI floor leveling compound.
Installation
When substrates require the combined use of both PCI Reinforcement Mats due to crack widths over 3 mm and expected movements, first lay PCI Reinforcement Mat GFS over the cracks of the prepared primed substrate, then fully embed PCI Reinforcement Mat GFM over it.
PCI Reinforcement Mat GFM
- Cut to size according to room dimensions or the area to be leveled, e.g., with scissors from the roll
- Lay over the prepared, primed, and dried substrate with approx. 1 cm overlap, then apply PCI floor leveling compound
| Safety Data Sheet | |||||||
|---|---|---|---|---|---|---|---|
| Label | Datenblatt | ||||||
| 250840.pdf | |||||||
| Reviewed by the supplier on | 12012009 | ||||||
| Occupational Safety and Storage | |||||||
| Storage classes | |||||||
| Non-combustible solid | |||||||
| Water Hazard Class | |||||||
| Water hazard class | 0 - not water hazardous | ||||||
| Ingredients | |||||||
| |||||||
Important Note: Individual sections are excluded from exchange or return.
- Item weight: 0,11 kg
- GoogleShopping: Hauptsortiment