Skip to consent manager Skip to main content Skip to search Skip to category navigation Skip to footer

PCI Apogel F Gieharz 2K 1kg

To compare cracks and expansion joints in screeds with crack or joint reinforcement
Information on product safety Manufacturer/EU Responsible Person

37,99 €
37,99 € per 1 kg
incl. 19% VAT , plus shipping costs
Available immediately
Delivery time: 2 - 3 Workdays (DE - int. shipments may differ)
Can(s)

Jetzt mit dem ChatGPT Assistenten chatten – Hilfe in Echtzeit!

PCI Apogel F Gieharz 2K 1kg
PCI Apogel F Gieharz 2K 1kg
37,99 € *
37,99 € per 1 kg
PCI Apogel F Gieszligharz for leveling and grouting of cracksProduct features - Transparent - Low viscosity penetrates even into the finest cracks and hollow areas - Secure adhesion even on moist substrates - Temperature resistant from 30 °C to 80 °C - Certified according to EN 15045 - With general building authority test certificate for LAU systems - Monitored by third parties - Color: transparent - Delivery forms: 1 kg canApplication areas - For interior and exterior use - Suitable for floors, walls, and ceilings - For leveling cracks and false joints in screeds with crack or joint reinforcement - For grouting cracks, false joints, and hollow areas in concrete and screed - Also applicable on moist crack faces - For creating force-fitting connections between cracked parts made of concrete and screed - For embedding PCI Apogel Du?belnSurface preparation - Cracks in concrete must be free of dirt and dust; crack faces can be moist - Before grouting, insert injection ports using drill or adhesive plugs - For moist cracks, use drill plugs - Insert drill plugs - Drill the component along the crack with a stone drill bit matching the packer diameter; the drill hole should cut approximately through the center of the crack in the component - Drill holes alternately on the left and right of the crack - The distance between drill holes should not exceed half the component thickness or 60 cm - Vacuum dust from the drill holes - Insert drill packers into the prepared holes and seal the cracks with the following PCI products: - PCI Polyfix 5 Min for crack grouting after 30 to 60 minutes or on moist surfaces - PCI Collastic for crack grouting after at least approx. 3 hours and during minor crack width changes during drying or grouting work - PCI Construction Resin or PCI Epoxy Primer 390 with PCI injection aid for high-pressure crack grouting after approx. 24 hours - Set adhesive plugs - Clean the component surfaces by sanding - Attach adhesive plugs with PCI Collastic or PCI Construction Resin over the crack - The plug spacing should correspond to the component thickness - Seal cracks as described for drill plugsCracks or false joints in screeds - Enlarge cracks or joints and remove loose or degraded parts from the edges - Open the cracks or joints with a grinding disc up to two-thirds of the screed thickness - For preparation of reinforcement, e.g., with PCI screed clamps, cut perpendicular to the crack direction - Saw cross slots in the substrate at a distance of approx. 10 to 20 cm, with a length of approx. 10 cm and a depth of about 2/3 of the screed thickness using a cutting disc - Thoroughly vacuum cracks and slotsNote: For heated screeds, repair may not be feasible depending on the construction type and the position of heating pipes due to the high risk of damage.Hollow areas in screeds - Locate and mark hollow areas in the screed plates by tapping - Drill perpendicular to the intact substrate in the hollow area - Depending on the size of the hollow, drill at the room edges of the hollow zone or in a suitable grid pattern - Vacuum the drill dust and insert drill packers - Leave two or more drill holes open in each hollow area to prevent foam-like fluid pressure during groutingProcessing of PCI Apogel - Wear suitable protective gloves and safety glasses or face protection; avoid spraying - PCI Apogel is supplied in the appropriate mixing ratio - Fully transfer the component to the base component and mix intensively with a clean, at least 2 cm wide and sufficiently long wooden spatula for about 2 minutes - After mixing, no streaks should be visible - Decant the homogeneous PCI Apogel into a clean container to ensure product homogeneity, avoiding dripping - Stir again before useGrouting of cracks or false joints in screeds - For narrow cracks up to approx. 2 mm, use PCI Apogel F or PCI Apogel Schnell - Cracks must be filled to a minimum depth of 5 mm or 15 times the crack width - For wider cracks, mix PCI Apogel with quartz sand and groutReinforcement - When grouting cracks, false joints, and cross slots with PCI Apogel, insert screed clamps into the cross slots - PCI screed clamps are available in cartons of 500 pieces - Excess or leaking material should be removed from the surface - After drying, if a bonded covering such as screed or tiles is applied, fully sprinkle the fresh PCI Apogel with quartz sand (grain size 0.3 to 0.8 mm)Safety data sheet - Please observe section 22 of the safety data sheetHazard information - The product contains epoxy compounds which may cause allergic reactions - Causes skin irritation - May cause allergic skin reactions - Causes serious eye irritation - Toxic to aquatic life with long-lasting effectsPrecautions - Avoid inhalation of dust, fumes, gas, mist, vapor, or aerosol - Wash thoroughly after use - Do not eat, drink, or smoke during use - Do not wear contaminated work clothing outside the workplace - Prevent release into the environment - Wear protective gloves, protective clothing, eye protection, face protection, and respiratory protection - In case of contact with eyes, rinse cautiously with water for several minutes; remove contact lenses if present and easy to do; continue rinsing - If inhaled, bring the person into fresh air and ensure unrestricted breathing - In case of skin contact, wash with water and soap - In case of eye contact, rinse cautiously with water for several minutes; remove contact lenses if present and easy to do; continue rinsing - If symptoms persist, seek medical advice - Remove contaminated clothing and wash before reuse - Collect spillage - Store in a tightly closed containerStorage class - Flammable liquids not classified under the above storage classesEnvironmental hazard class - Water hazard class 2 (water hazardous)Transport hazard symbols - GHS05: Corrosive - GHS07: Harmful - GHS09: Environmentally hazardousIngredients - CAS 2855132: 90530204: 25513648 - The product contains epoxy compounds which may cause allergic reactions, skin irritation, serious skin and eye damage, and long-term aquatic toxicity.

Product safety information
Manufacturer information:
PCI Augsburg GmbH
Piccardstraße 11
Baden-Württemberg
Augsburg, Deutschland, 86159
info@pci-augsburg.de
https://www.pci-augsburg.de
Responsible person:
PCI Augsburg GmbH
Piccardstraße 11
Baden-Württemberg
Augsburg, Deutschland, 86159
info@pci-augsburg.de
https://www.pci-augsburg.de
  • Container: Can
  • Item weight: 1,33 kg
  • Content: 1,00 kg
  • GoogleShopping: Hauptsortiment

Write the first review for this item and help others make a purchase decision!:

Contact data
All fields marked with * are mandatory fields.
Question about item

Please see our privacy notice

Loading ...