Go to the consent manager Skip to main content Skip to search Skip to navigation Jump to footer
PCI Nanocret FC Concrete Putty 25 kg Bag
PCI Nanocret FC low-voltage weather-resistant and weatherproof fiber-reinforced concrete filler

Mit dem Bauschnell ChatGPT Assistent chatten

Information on product safety Manufacturer EU Responsible Person

Versions
39,90 €
1,60 € per 1 kg
incl. 19% VAT , plus shipping costs
Available immediately
Delivery time: 2 - 3 Workdays (DE - int. shipments may differ)
Bag(s)
pci nanocret fc faserverstärkter betonspachtel grau...
PCI Nanocret FC Concrete Putty 25 kg Bag
39,90 € *
1,60 € per 1 kg
1,60 € per 1 kg

PCI Nanocret FC low-voltage weather-resistant and weather-resistant concrete filler fiber-reinforced

Product features

  • Low-voltage, durable, weather and frost-resistant, universal for interior and exterior use
  • Becomes plastic and smooth after water addition, easy to process
  • Fast setting, yet approximately 45 minutes working time
  • Fine-grained surface, no overcoating required
  • Machine and hand processable
  • Tested according to DAfStb guideline for the protection and repair of concrete components
  • Certified according to EN 15043 R2

Colors: gray, gray-brown

Delivery forms: 25kg sack, 5kg bag

Application area

  • For interior and exterior use
  • For wall and ceiling
  • For repairing gravel nests, filling cavities
  • For overcoating masonry and cement plaster
  • As concrete filler on concrete, visible and porous concrete
  • To level uneven wall surfaces before laying tiles and slabs
  • As leveling mortar in swimming pools
  • Fine plaster after concrete restoration with PCI Peciment 50 on vertical and non-trafficable exposed concrete surfaces in engineering and bridge construction according to ZTVING for the application PCC II, non-trafficable surfaces subjected to dynamic loads, e.g., bridge undersides
  • As fine filler for OS4 or OS 5a coatings according to DAfStb
  • For layer thicknesses of 1 to 10 mm

Substrate preparation

The substrate must be clean, firmly bonded, open-pored, absorbent, and sufficiently rough. The minimum quality standards for concrete substrates must meet C20/25. Extremely dense, smooth substrates, as well as non-load-bearing layers and foamed concrete surfaces, must be removed using suitable methods such as blasting with solid abrasive media or high-pressure water jetting.

The bond tensile strength of a prepared concrete substrate must not be less than 0.8 N/mm².

The pretreated substrate should be sufficiently moist and pre-wetted about 2 hours before applying PCI Nanocret FC. The surface must be matt and moist.

Priming

On absorbent cementitious substrates, the substrate can be troweled without primer if pre-wetted to a matte moist state.

Highly absorbent substrates, e.g., porous concrete, should be pre-wetted or primed with PCI Gisogrund 1, diluted 1:1 to 1:2 with water.

Non-absorbent substrates should be primed with PCI Gisogrund 303.

Processing PCI Nanocret FC

Mix approximately 55% of the cold mixing water in a clean container. Then add 25 kg PCI Nanocret FC and mix for 3 minutes to a lump-free, plastic mortar. Larger quantities can be mixed in a forced mixer.

After a maturation time of about 3 minutes, remix PCI Nanocret FC.

The mortar can be processed using standard techniques such as troweling with a smoothing trowel—first apply a contact layer to the substrate. Small gaps can be filled with a steel trowel, larger surfaces leveled with a straightedge in horizontal and vertical directions.

For machine application via spraying, first spray a thin contact layer, then apply PCI Nanocret FC in the desired layer thickness.

After the mortar has set, approximately 45 to 90 minutes depending on substrate and processing temperature, PCI Nanocret FC can be smoothed with damp Styrofoam, felt, or sponge board without additional water.

In high temperatures, wind exposure, and direct sunlight, prevent premature drying of the mortar, e.g., by spraying with water multiple times, covering with jute mats or PE foil.

Safety Data Sheet

Safety Data Sheet

Safety Data Sheet PDF
01.09.2016

Work safety and storage

H315

Causes skin irritation

H318

Causes serious eye damage

H335

May cause respiratory irritation
Please observe section 22 of the safety data sheet

P102

Keep out of reach of children

P261

Avoid inhalation of dust, fumes, gas, mist, vapor, aerosol

P264

Wash thoroughly after handling

P280

Wear protective gloves, protective clothing, eye protection, face protection

P302/P352

IF ON SKIN: Wash with plenty of water

P304/P340

IF INHALED: Bring the person into fresh air and ensure unrestricted breathing

P305/P351/P338

IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do. Continue rinsing

P315

Seek immediate medical advice

P332/P313

If skin irritation occurs: seek medical advice

P362/P364

Contaminated clothing should be removed and washed before reuse

Class 13

Non-combustible solid
Low water hazard

Hazard statement

: Gefahr

Aumltzend Reizend
GHS05 Reizend
Gesundheitsgefaumlhrdend
GHS07 Health hazard

Ingredients

Ingredients

CAS NumberIntake routeSubstance name
65997-15-1Silica fume
130562-0Cement

  • Container: Bag
  • Item weight: 25,10 kg
  • Content: 25,00 kg
  • GoogleShopping: Hauptsortiment

Technisches Datenblatt:

Sicherheitsdatenblatt:

Write the first review for this item and help others make a purchase decision!:

Contact data
All fields marked with * are mandatory.
Question about item

Please see our privacy notice

Loading ...